COLOUR SPECTROPHOTOMETER

3nh Colour Spectrophotometers

Colour spectrophotometers from 3nh Technology are popular colour measurement instruments preferredin several different industries. As colour assessment is applicable to a wide spectrum of application areas, 3nh Technology offers different systems suitable for varied applications, including portable and bench-top spectrophotometers, spectro-densitometers, and grating spectrophotometers.

Portable Colour Spectrophotometers – NS Series

The NS series spectrophotometers are handy and portable colour measurement systems ideal for on-site applications. It has two models – NS800 and NS810. Both the models have several common specifications and are equipped with 3.5” touch screens.

The size of their integrating spheres is Φ58mm, while their wavelength range is 400~700nm and measuring aperture Φ8mm. With both the systems, you can assess colour in different colour spaces such as CIE LAB, XYZ, Yxy, LCh, CIE LUV, LAB&WI&YI. The major difference between the NS800 and NS810 is in the illumination/observation system. The NS800 is equipped with a 45/0 method (45 ring-shaped illumination, vertical viewing) and the NS810 has d/8 (diffused illumination, 8-degree viewing angle).

NS Spectrophotometer Models

Model

 NS800

 Illumination/observation system

 45/0 method (45 ring-shaped illumination, vertical viewing), Comply with CIE No.15,GB/T 3978

 Integrating sphere Size

 Φ58mm

 Light Source

 combined LED sources

 Sensor

 Silicon photodiode array

 Wavelength range

 400~700nm

 Wavelength interval

 10nm

 Reflectance range

 0~200%

 Measuring Aperture

 Φ8mm

 Color Space

 CIE LAB,XYZ,Yxy,LCh,CIE LUV

 Color difference Formula

 ΔE*ab,ΔE*uv,ΔE*94,ΔE*cmc(2:1),ΔE*cmc(1:1),ΔE*00

 Other Chromaticity Data

 WI(ASTM E313,CIE/ISO, AATCC, Hunter), YI(ASTM D1925,ASTM  313), Metamerism Index (Mt), Color Stain,  Color Fastness

 Observer

 2°/10°

 Illuminant

 D65,A,C,D50,D55,D75,F2,F6,F7,F8,F10,F11,F12

 Display Data

 Spectral Value/Graph, Colorimetric Value, Color Difference  Value/Graph, PASS/FAIL Result, Color Offset, Color Simulation  

 Measurement Time

 1.5s

 Repeatability

 Spectral Reflectance: standard deviation within 0.1%(400~700nm:  within 0.2%)

 Colorimetric Value

 Standard deviation within Delta E*ab 0.04 (Measurement conditions:  white calibration plate measured 30 times at 5 seconds intervals after  white calibration was performed.)

 Inter Instrument Agreement

 Within Delta E*ab 0.2 (Average for 12 BCRA Series II color tiles)

 Display Screen

 TFT 3.5inch, Capacitive Touch Screen

 Interface

 USB/RS-232

 Data Memory

 1000 Standards, 15000 Samples

 Standard Accessory

 Power Adapter, Li-ion Battery, Operating Instruction, CD-ROM  (containing management software), Data Line, White and Black  Calibration Cavity, Protective Cover and Wrist Strap

 Others

 Provide complete spectrum reflectance curve, Input L, a, b value  manually

ModelNS810
Illumination/observation systemd/8 (diffused illumination, 8 degree viewing angle) Conforms to CIE No.15, GB/T 3978.
Integrating sphere SizeΦ58mm
Light SourceCombined LED sources
SensorSilicon photodiode array
Wavelength range400~700nm
Wavelength pitch10nm
Reflectance range0~200%
Measuring ApertureΦ8mm
Color SpaceCIE LAB, XYZ, Yxy, LCh, CIE LUV,LAB&WI&YI
Color difference FormulaΔE*ab, ΔE*uv, ΔE*94, E*cmc(2:1), ΔE*cmc(1:1), ΔE*cmc(l:c), CIE2000ΔE*00,ΔE(h)
Other Chromaticity DataWI(ASTM E313,CIE/ISO,AATCC, Hunter),
 YI(ASTM D1925,ASTM 313),
 TI(ASTM E313,CIE/ISO),
 Metamerism Index (Mt), Strength
 Color Stain, Color Fastness
Observer2°/10°
IlluminantD65,A, C, D50,D55,D75,F1,F2(CWF), F3,F4,F5,F6,F7(DLF),F8,F9,F10(TPL5) F11 (TL84), F12 (TL83/U30)
Display DataSpectral Value/Graph, Colorimetric Value, Color Difference Value / Graph, PASS / FAIL Result, Color Offset, Color Simulation, color index setting (ΔE * 94, ΔE*cmc, ΔE2000 ), tolerance prompt, reverse prompt, time setting,  language setting, restore factory setting
Measurement Time1.2s
RepeatabilitySpectral Reflectance: standard deviation within 0.1 %400 ~ 700 nm : within 0.2%
 Colorimetric Value: Standard deviation within 
DeltaE*ab 0.04 ( Measurement conditions: white calibration plate measured 30 times at 5 seconds intervals after white calibration was performed.)
Inter Instrument AgreementWithin DeltaE*ab 0.2 (Average for 12
 BCRA Series II color tiles)
Display ScreenTFT 3.5inch, Capacitive Touch Screen
InterfaceUSB/RS-232
Data Memory1000 Standards, 15000 Samples
Standard AccessoryPower Adapter, Li-ion Battery, Operating Instruction, CD-ROM (containing management software), Data Line, White and Black Calibration Cavity, Protective 
Cover and Wrist Strap

Spectro-Densitometers

3nh also offers a unique range of spectro-densitometers which are specifically used in industries such as printing, film processing, textile printing & dyeing, and plastic electronics. This is the reason they are sometimes referred to as pressroom densitometers. The 3nh spectro-densitometer models YD5050 and YD5010 measure and display the density of ink on a colour bar, based on which the operator can decide on adjusting the ink levels.

YD Spectrodensitometer Models:

Model

YD5010

Measurement Geometry

45/0(45 ring-shaped illumination, 0 degree viewing angle); ISO 5-4,CIE No.15

Features

Common spectrophotometer densitometer, apply in ink printing, in Film Processing, Textile Printing and Dyeing, Plastic Electronics and Other Industries for Color Measurement and Quality Control;especially suitable for the measurement and quality control of optical density and dot enlargement in ink printing;able to customize single aperture Φ2mm,Φ4mm,Φ8mm.

Light Source

Combined LED Light, UV Light

Spectral separation device

Concave Grating

Detector

256 Image Element Double Array CMOS Image Sensor

Wavelength Range

400~700nm

Wavelength Pitch

10nm

Half Bandwidth

10nm

Measurement Conditions

Compliance with ISO 13655 measurement conditions;
M0 (CIE Light Soure A)
M1 (CIE Light Soure D50)
M2 (Excluding UV light source)
M3 (M2+Polarized light filter)

Density Standards

ISO Status A, E, I, T

Density index

Density value, density difference, dot area, dot enlargement, overprint, printing characteristics, printing contrast, tone error and gray level

Measurement aperture

Customized one aperture:Φ2mm,Φ4mm,Φ8mm optional

Color Spaces

CIE LAB,XYZ,Yxy,LCh

Color Difference Formula

ΔE*ab,ΔE*94,ΔE*00

Other Colorimetric Index

/

Observer Angle

2°/10°

Illuminants

A,C,D50,D55,D65,D75,F2,F7,F11,F12

Measurement Time

About 1.5s

Repeatability

Density: Within 0.01 D

 

Chromaticity value:within ΔE*ab 0.04 (When a white calibration plate is measured 30 times at 5 second intervals after white calibration) Except M3

Inter-instrument Error

Within ΔE*ab 0.2 (Average for 12 BCRA Series II color tiles) Except M3

Measurement mode

Single Measurement, Average Measurement(2-99)

Display

3.5-inch TFT color LCD, Capacitive Touch Screen

Data memory

10000 pcs

Standard Accessory

Power Adapter, USB Cable, Built-in li-ion battery, User Manual, software(download from the website),White and Black Calibration Board, Protective Cover,Polarization filter box,Locating Plate

ModelYD5050
Measurement Geometry45/0(45 ring-shaped illumination, 0 degree viewing angle); ISO 5-4,CIE No.15
Featureshigh accuracy spectrophotometer densitometer, apply in ink printing, in Film Processing, Textile Printing and Dyeing, Plastic Electronics and Other Industries for Color Measurement and Quality Control;especially suitable for the measurement and quality control of optical density and dot enlargement in ink printing;able to customize single aperture Φ2mm,Φ4mm,Φ8mm.
Light SourceCombined LED Light, UV Light
Spectral separation deviceConcave Grating
Detector256 Image Element Double Array CMOS Image Sensor
Wavelength Range400~700nm
Wavelength Pitch10nm
Half Bandwidth10nm
Measurement ConditionsCompliance with ISO 13655 measurement conditions; M0 (CIE Light Soure A) M1 (CIE Light Soure D50) M2 (Excluding UV light source) M3 (M2+Polarized light filter)
Density StandardsISO Status A, E, I, T
Density indexDensity value, density difference, dot area, dot enlargement, overprint, printing characteristics, printing contrast, tone error and gray scale, density scanning
Measurement apertureCustomized one aperture:Φ2mm,Φ4mm,Φ8mm optional
Color SpacesCIE LAB,XYZ,Yxy,LCh,CIE LUV,HunterLAB
Color Difference FormulaΔE*ab, ΔE*94, ΔE*00, ΔE*uv, ΔE*cmc(2:1), ΔE*cmc(1:1), ΔE(Hunter)
Other Colorimetric IndexWI(ASTM E313,CIE/ISO,AATCC,Hunter), YI(ASTM D1925,ASTM 313), MI (Metamerism Index),Opacity,
Observer Angle2°/10°
IlluminantsA, C, D50, D55, D65, D75, F2(CWF), F7(DLP), F11(TL84), F12(TL83/U30), F1, F3, F4, F5, F6, F8, F9, F10(TPL5)
Measurement TimeAbout 1.5s
RepeatabilityDensity: Within 0.01 D
Chromaticity value:within ΔE*ab 0.03 ( When a white calibration plate is measured 30 times at 5 second intervals after white calibration)  Except M3
Inter-instrument ErrorWithin ΔE*ab 0.18 (Average for 12 BCRA Series II color tiles) Except M3
Measurement modeSingle Measurement, Average Measurement(2-99)
Display3.5-inch TFT color LCD, Capacitive Touch Screen
InterfaceUSB, Bluetooth 4.0
Data memory20000 pcs
Standard AccessoryPower Adapter, USB Cable, Built-in li-ion battery, User Manual, software(download from the website),White and Black Calibration Board, Protective Cover,Polarization filter box,Locating Plate

Grating Spectrophotometers

3nh manufacture both bench-top and portable models of grating spectrophotometers. TS7600 and TS7700 are the portable models while the bench-top variants are YS6010 and YS6060.

The portable models are equipped with a silicon photodiode array sensor and an integrating sphere size of Φ40mm. Both the systems can measure various colour spaces such as CIE LAB, XYZ, Yxy, LCh, CIE LUV, and s-RGB. The TS770 has a UV light source in addition to the conventional combined full spectrum LED light source and can provide colour values in the popular HunterLab colour space. They are equipped with TFT colour touch screens for easy operation and navigation.

The bench top models are preferred for R&D applications in laboratory environments. The YS6010 and YS6060 are equipped with an integrating sphere size of Φ154mm and wavelength range of 360 – 780 nm. These systems are equipped with a high-quality 256 image element double array CMOS image sensor. The YS6010 and YS6060 colour spectrophotometers are equipped with built-in memories that can store up to 20,000 and 40,000 results each.

Grating Spectrophotometer Models:

Model

TS7600

Optical Geometry

Reflect: di:8°, de:8°(diffused illumination, 8-degree viewing angle);
SCI (specular component included)/SCE (specular component excluded) ,excluded UV light source;
Conforms to CIE No.15,GB/T 3978,GB 2893,GB/T 18833,ISO7724-1,ASTM E1164,DIN5033 Teil7;

Characteristic

Customized one aperture, It is used for precise color measurement and quality control in plastic electronics, paint and ink, textile and garment printing and dyeing, printing, ceramics and other industries, and for fluorescent sample measurement.

Integrating Sphere Size

Φ40mm

Light Source

Combined full spectrum LED light source

Spectrophotometric Mode

Flat Grating

Sensor

Silicon photodiode array (double row 40 groups)

Wavelength Range

400~700nm

Wavelength Interval

10nm

Semiband Width

10nm

Measured Reflectance Range

0-200%

Measuring Aperture

Customized one aperture: MAV:Φ8mm/Φ10mm;SAV:Φ4mm/Φ5mm

Specular Component

SCI&SCE

Color Space

CIE LAB,XYZ,Yxy,LCh,CIE LUV,s-RGB,βxy,Munsell(C/2)

Color Difference Formula

ΔE*ab,ΔE*uv,ΔE*94,ΔE*cmc(2:1),ΔE*cmc(1:1),ΔE*00

Other Colorimetric Index

WI(ASTM E313,CIE/ISO,AATCC,Hunter),
YI(ASTM D1925,ASTM 313),
Staining Fastness, Color Fastness, Color Strength, Opacity,
8° Glossiness,

Observer Angle

2°/10°

Illuminant

D65,A,C,D50,F2(CWF),F7(DLF),F10(TPL5),F11(TL84),F12(TL83/U30)

Displayed Data

Spectrogram/Values, Samples Chromaticity Values, Color Difference Values/Graph, PASS/FAIL Result, Color Offset

Measuring Time

About 1.5s (Measure SCI & SCE about 3.2s)

Repeatability

Spectral reflectance: MAV/SCI, Standard deviation within 0.1% (400 nm to 700 nm: within 0.2%)
Chromaticity value: MAV/SCI, within ΔE*ab 0.04 ( When a white calibration plate is measured 30 times at 5 second intervals after white calibration)

Inter-instrument Error

MAV/SCI, Within ΔE*ab 0.2
(Average for 12 BCRA Series II color tiles)

Measurement Mode

Single Measurement, Average Measurement(2-99times)

Locating Method

Camera Locating,stabilizer cross position

Displayed Data

3.5-inch TFT color LCD, Capacitive Touch Screen

Data Port

USB

Data Storage

Standard 1000 Pcs, Sample 20000 Pcs

Standard Accessory

Power Adapter, User Guide, PC Software(Download from office website), USB cable, White and Black Calibration Cavity, Protective Cover, Wrist strap, One aperture (8mm or 4mm)

Model

TS7700

Optical Geometry

Reflect: di:8°, de:8°(diffused illumination, 8-degree viewing angle)

SCI (specular component included)/SCE (specular component excluded) ;      Include UV / excluded UV light source

Conforms to CIE No.15,GB/T 3978,GB 2893,GB/T 18833,ISO7724-1,ASTM E1164,DIN5033 Teil7

Characteristic

double apertures for accurate color analysis and transmission in laboratory

It is used for precise color measurement and quality control in plastic electronics, paint and ink, textile and garment printing and dyeing, printing, ceramics and other industries, and for fluorescent sample measurement.

Integrating Sphere Size

Φ40mm

Light Source

Combined full spectrum LED light source, UV light source

Spectrophotometric Mode

Flat Grating

Sensor

Silicon photodiode array (double row 40 groups)

Wavelength Range

400~700nm

Wavelength Interval

10nm

Semiband Width

10nm

Measured Reflectance Range

0-200%

Measuring Aperture

MAV:Φ8mm/Φ10mm;SAV:Φ4mm/Φ5mm

Specular Component

SCI&SCE

Color Space

CIE LAB,XYZ,Yxy,LCh,CIE LUV,s-RGB,HunterLab,βxy,DIN Lab99 Munsell(C/2)

Color Difference Formula

ΔE*ab,ΔE*uv,ΔE*94,ΔE*cmc(2:1),ΔE*cmc(1:1),ΔE*00, DINΔE99,ΔE(Hunter)

Other Colorimetric Index

WI(ASTM E313,CIE/ISO,AATCC,Hunter),

YI(ASTM D1925,ASTM 313),

Metamerism Index MI,

Staining Fastness, Color Fastness, Color Strength, Opacity,

8° Glossiness,555 tone classification

Observer Angle

2°/10°

Illuminant

D65,A,C,D50,D55,D75,F1,F2(CWF),F3,F4,F5,F6,F7(DLF),F8,F9,F10(TPL5),F11(TL84),F12(TL83/U30)

Displayed Data

Spectrogram/Values, Samples Chromaticity Values, Color Difference Values/Graph, PASS/FAIL Result, Color Offset

Measuring Time

About 1.5s (Measure SCI & SCE about 3.2s)

Repeatability

Spectral reflectance: MAV/SCI, Standard deviation within 0.08% (400 nm to 700 nm: within 0.18%)

Chromaticity value: MAV/SCI, within ΔE*ab 0.02 ( When a white calibration plate is measured 30 times at 5 second intervals after white calibration)

Inter-instrument Error

MAV/SCI, Within ΔE*ab 0.15
(Average for 12 BCRA Series II color tiles)

Measurement Mode

Single Measurement, Average Measurement(2-99times)

Locating Method

Camera Locating,stabilizer cross position

Dimension

L*W*H=129X76X217mm

Weight

Approx 600g

Battery

3.7V,5000mAh Li-ion battery, 6000 measurements within 8 hours

Illuminant Life Span

5 years, more than 3 million times measurements

Displayed Data

3.5-inch TFT color LCD, Capacitive Touch Screen

Data Port

USB, Bluetooth 4.2

Data Storage

Standard 1000 Pcs, Sample 30000 Pcs

Standard Accessory

Power Adapter, User Guide, PC Software(Download from office website), USB cable, White and Black Calibration Cavity, Protective Cover, Wrist strap, 8mm flat aperture, 8mm tip aperture, 4mm flat aperture, 4mm tip aperture

Optional Accessory

Micro Printer, Powder Test Box

Model

YS6010 Benchtop Spectrophotometer

Optical Geometry

Reflect: di:8°, de:8°(diffused illumination, 8-degree viewing angle) ;         
SCI (specular component included)/SCE (specular component excluded) ;       Include UV / excluded UV light source
Transmittance: di:0°, de:0° (diffuse illumination: 0° viewing) ;                     
SCI (specular component included)/SCE (specular component excluded) ;       Include UV / excluded UV light source;
Haze(ASTM D1003),
Conforms to CIE No.15,GB/T 3978,GB 2893,GB/T 18833, ISO7724/1, ASTM E1164, DIN5033 Teil7

Application

It is used for accurate analysis and transmission of laboratory color.     Apply in paints, inks, textiles, garments, printing and dyeing, printing etc industries for color transfer and quality control.

Integrating Sphere Size

Φ154mm

Light Source

360 nm to 780 nm, Combined LED Light, 400nm cut-off light source

Spectrophotometric Mode

Concave Grating

Sensor

256 Image Element Double Array CMOS Image Sensor

Wavelength Range

360-780nm

Wavelength Interval

10nm

Semiband Width

10nm

Measured Reflectance Range

0-200%

Measuring Aperture

Reflective: Φ30mm/Φ25.4mm, Φ10mm/Φ8mm, Φ6mm/Φ4mm;
Transmissive: Φ30mm/Φ25mm;                     
Remark: 1. Automatic identification of switch caliber   2. Customized Configuration caliber and lens position

Specular Component

Reflectance: SCI&SCE / Transmittance: SCI&SCE

Color Space

CIE LAB,XYZ,Yxy,LCh,CIE LUV,Musell,s-RGB,HunterLab,βxy,DIN Lab99

Color Difference Formula

ΔE * ab ,ΔE * uv ,ΔE * 94 ,ΔE * cmc(2:1) ,ΔE * cmc(1:1) ,ΔE * 00 , DINΔE 99 ,ΔE (Hunter),

Other Colorimetric Index

WI (ASTM E313, CIE/ISO, AATCC, Hunter),
YI (ASTM D1925, ASTM 313),
MI (Metamerism Index),
Staining Fastness, Color Fastness, Color Strength, Opacity,
8° Glossiness,Gardner Index, APHA/Pt-Co Index, 555 Index, Haze(ASTM D1003),Saybolt

Observer Angle

2°/10°

Illuminant

D65,A,C,D50,D55,D75,F1,F2,F3,F4,F5,F6,F7,F8,F9,F10,F11,F12,CWF,DLF,TL83,TL84,TPL5,U30

Displayed Data

Spectrogram/Values, Samples Chromaticity Values, Color Difference Values/Graph, PASS/FAIL Result, Color Offset

Measuring Time

About 2.4s (Measure SCI & SCE about 5s)

Repeatability

Spectral reflectance: Φ25.4mm/SCI, Standard deviation within 0.05% (400 nm to 700 nm: within 0.04%)
Chromaticity value:Φ25.4mm/SCI, Standard deviation within ΔE*ab 0.02 ( When a white calibration plate is measured 30 times at 5 second intervals after white calibration)  Spectral Transmittance: Φ25.4mm/SCI, Standard deviation within 0.05% (400 nm to 700 nm: within 0.04%)
Chromaticity value:Φ25.4mm/SCI, Standard deviation within ΔE*ab 0.03 ( When a white calibration plate is measured 30 times at 5 second intervals after white calibration)

Inter-instrument Error

Φ25.4mm/SCI, Within ΔE*ab 0.15

(Average for 12 BCRA Series II color tiles)

Illuminant Life Span

5 years, more than 3 million times measurements

Display

7-inch TFT color LCD, Capacitive Touch Screen

Data Port

USB & Print serial port

Data Storage

Standard 2000 Pcs, Sample 20000 Pcs

Standard Accessory

Power Adapter, User Guide, CD Disk(PC Software), USB cable, Standard Calibration Board, Black Calibration Cavity, Transmission black baffle, Sample holder, 25.4 caliber, 8 caliber, 4 caliber

Optional Accessory

Micro-printer, Transmissive Test Component, Micro Aperture(4mm) transmission test clamp component, Instrument inversion components,culture d

Model

YS6060 Benchtop Spectrophotometer

Optical Geometry

Reflect: di:8°, de:8°(diffused illumination, 8-degree viewing angle) ;         
SCI (specular component included)/SCE (specular component excluded) ; Include UV / excluded UV light source
Transmittance: di:0°, de:0° (diffuse illumination: 0° viewing) ;                     
SCI (specular component included)/SCE (specular component excluded) ; Include UV / excluded UV light source;
Haze(ASTM D1003),
Conforms to CIE No.15,GB/T 3978,GB 2893,GB/T 18833, ISO7724/1, ASTM E1164, DIN5033 Teil7

Application

It is used for accurate analysis and transmission of laboratory color.     Apply in paints, inks, textiles, garments, printing and dyeing, printing etc industries for color transfer and quality control.

Integrating Sphere Size

Φ154mm

Light Source

360 nm to 780 nm, Combined LED Light, 400nm cut-off light source,420nmCut-off light source

Spectrophotometric Mode

Concave Grating

Sensor

256 Image Element Double Array CMOS Image Sensor

Wavelength Range

360-780nm

Wavelength Interval

10nm

Semiband Width

5nm

Measured Reflectance Range

0-200%

Measuring Aperture

Reflective : Φ30mm/Φ25.4mm, Φ18mm/Φ15mm, Φ10mm/Φ8mm, Φ6mm/Φ4mm;
Transmissive : Φ30mm/Φ25mm;                         
Remark: 1. Automatic identification of switch caliber   2. Customized Configuration caliber and lens position

Specular Component

Reflectance: SCI&SCE  / Transmittance: SCI&SCE

Color Space

CIE LAB,XYZ,Yxy,LCh,CIE LUV,Musell,s-RGB,HunterLab,βxy,DIN Lab99

Color Difference Formula

ΔE * ab ,ΔE * uv ,ΔE * 94 ,ΔE * cmc(2:1) ,ΔE * cmc(1:1) ,ΔE * 00 , DINΔE 99 ,ΔE (Hunter),

Other Colorimetric Index

WI (ASTM E313, CIE/ISO, AATCC, Hunter),
YI (ASTM D1925, ASTM 313),
MI (Metamerism Index),
Staining Fastness, Color Fastness, Color Strength, Opacity,
8° Glossiness,Gardner Index,APHA/ Pt-Co Index, 555 Index, Haze(ASTM D1003),Saybolt

Observer Angle

2°/10°

Illuminant

D65,A,C,D50,D55,D75,F1,F2,F3,F4,F5,F6,F7,F8,F9,F10,F11,F12,CWF,DLF,TL83,TL84,TPL5,U30

Displayed Data

Spectrogram/Values, Samples Chromaticity Values, Color Difference Values/Graph, PASS/FAIL Result, Color Offset

Measuring Time

About 2.4s (Measure SCI & SCE about 5s)

Repeatability

Spectral reflectance: Φ25.4mm/SCI, Standard deviation within 0.04% (400 nm to 700 nm: within 0.04%)
Chromaticity value:Φ25.4mm/SCI, Standard deviation within ΔE*ab 0.01 ( When a white calibration plate is measured 30 times at 5 second intervals after white calibration)                                                                                        Spectral Transmittance: Φ25.4mm/SCI, Standard deviation within 0.05% (400 nm to 700 nm: within 0.04%)
Chromaticity value:Φ25.4mm/SCI, Standard deviation within ΔE*ab 0.02 ( When a white calibration plate is measured 30 times at 5 second intervals after white calibration)

Inter-instrument Error

Φ25.4mm/SCI, Within ΔE*ab 0.12

 

(Average for 12 BCRA Series II color tiles)

Dimension

L*W*H=370x300x200mm

Illuminant Life Span

5 years, more than 3 million times measurements

Display

7-inch TFT color LCD, Capacitive Touch Screen

Data Port

USB & Bluetooth & Print serial port

Data Storage

Standard 5000 Pcs, Sample 40000 Pcs

Standard Accessory

Power Adapter, User Guide, CD Disk(PC Software), USB cable, Standard Calibration Board, Black Calibration Cavity, Transmission black baffle, Sample holder, 25.4 caliber, 15 caliber, 8 caliber, 4 caliber,Transmissive Test Component

Optional Accessory

Micro-printer,  Micro Aperture(4mm) transmission test clamp component, Instrument inversion components,culture dish

Additional Accessories To Colour Spectrophotometers

Powder Test Box

For efficient measurement of the colour of powders, pellets, granules, and products of their like, the powder test box is a vital accessory. The powder test box should be filled up to 1/3rds of its capacity and attached to the spectrophotometer to measure colour values of the sample.

Universal Test Component

The universal test component is an accessory spectrophotometers which is used for assessing the colour of liquids, powders, and pastes.

3nh Colour Spectrophotometer Applications

  • Plastics
  • Paints & inks
  • Printing
  • Cosmetics
  • Textile
  • Leather
  • Paper
  • Food

3nh Colour Spectrophotometer Price

Agaram Industries is the authorized distributor of Shenzhen 3nh Technology Co. Ltd. colour spectrophotometers in India. To get a quotation with the colour spectrophotometer price, you can fill up this form or directly send an email to sales@agaramindia.com.