COLOUR SPECTROPHOTOMETER
3nh Colour Spectrophotometers
Colour spectrophotometers from 3nh Technology are popular colour measurement instruments preferredin several different industries. As colour assessment is applicable to a wide spectrum of application areas, 3nh Technology offers different systems suitable for varied applications, including portable and bench-top spectrophotometers, spectro-densitometers, and grating spectrophotometers.
Portable Colour Spectrophotometers – NS Series
The NS series spectrophotometers are handy and portable colour measurement systems ideal for on-site applications. It has two models – NS800 and NS810. Both the models have several common specifications and are equipped with 3.5” touch screens.
The size of their integrating spheres is Φ58mm, while their wavelength range is 400~700nm and measuring aperture Φ8mm. With both the systems, you can assess colour in different colour spaces such as CIE LAB, XYZ, Yxy, LCh, CIE LUV, LAB&WI&YI. The major difference between the NS800 and NS810 is in the illumination/observation system. The NS800 is equipped with a 45/0 method (45 ring-shaped illumination, vertical viewing) and the NS810 has d/8 (diffused illumination, 8-degree viewing angle).
NS Spectrophotometer Models
- NS 800
- NS 810
Model | NS800 |
Illumination/observation system | 45/0 method (45 ring-shaped illumination, vertical viewing), Comply with CIE No.15,GB/T 3978 |
Integrating sphere Size | Φ58mm |
Light Source | combined LED sources |
Sensor | Silicon photodiode array |
Wavelength range | 400~700nm |
Wavelength interval | 10nm |
Reflectance range | 0~200% |
Measuring Aperture | Φ8mm |
Color Space | CIE LAB,XYZ,Yxy,LCh,CIE LUV |
Color difference Formula | ΔE*ab,ΔE*uv,ΔE*94,ΔE*cmc(2:1),ΔE*cmc(1:1),ΔE*00 |
Other Chromaticity Data | WI(ASTM E313,CIE/ISO, AATCC, Hunter), YI(ASTM D1925,ASTM 313), Metamerism Index (Mt), Color Stain, Color Fastness |
Observer | 2°/10° |
Illuminant | D65,A,C,D50,D55,D75,F2,F6,F7,F8,F10,F11,F12 |
Display Data | Spectral Value/Graph, Colorimetric Value, Color Difference Value/Graph, PASS/FAIL Result, Color Offset, Color Simulation |
Measurement Time | 1.5s |
Repeatability | Spectral Reflectance: standard deviation within 0.1%(400~700nm: within 0.2%) |
Colorimetric Value | Standard deviation within Delta E*ab 0.04 (Measurement conditions: white calibration plate measured 30 times at 5 seconds intervals after white calibration was performed.) |
Inter Instrument Agreement | Within Delta E*ab 0.2 (Average for 12 BCRA Series II color tiles) |
Display Screen | TFT 3.5inch, Capacitive Touch Screen |
Interface | USB/RS-232 |
Data Memory | 1000 Standards, 15000 Samples |
Standard Accessory | Power Adapter, Li-ion Battery, Operating Instruction, CD-ROM (containing management software), Data Line, White and Black Calibration Cavity, Protective Cover and Wrist Strap |
Others | Provide complete spectrum reflectance curve, Input L, a, b value manually |
Model | NS810 |
Illumination/observation system | d/8 (diffused illumination, 8 degree viewing angle) Conforms to CIE No.15, GB/T 3978. |
Integrating sphere Size | Φ58mm |
Light Source | Combined LED sources |
Sensor | Silicon photodiode array |
Wavelength range | 400~700nm |
Wavelength pitch | 10nm |
Reflectance range | 0~200% |
Measuring Aperture | Φ8mm |
Color Space | CIE LAB, XYZ, Yxy, LCh, CIE LUV,LAB&WI&YI |
Color difference Formula | ΔE*ab, ΔE*uv, ΔE*94, E*cmc(2:1), ΔE*cmc(1:1), ΔE*cmc(l:c), CIE2000ΔE*00,ΔE(h) |
Other Chromaticity Data | WI(ASTM E313,CIE/ISO,AATCC, Hunter), |
YI(ASTM D1925,ASTM 313), | |
TI(ASTM E313,CIE/ISO), | |
Metamerism Index (Mt), Strength | |
Color Stain, Color Fastness | |
Observer | 2°/10° |
Illuminant | D65,A, C, D50,D55,D75,F1,F2(CWF), F3,F4,F5,F6,F7(DLF),F8,F9,F10(TPL5) F11 (TL84), F12 (TL83/U30) |
Display Data | Spectral Value/Graph, Colorimetric Value, Color Difference Value / Graph, PASS / FAIL Result, Color Offset, Color Simulation, color index setting (ΔE * 94, ΔE*cmc, ΔE2000 ), tolerance prompt, reverse prompt, time setting, language setting, restore factory setting |
Measurement Time | 1.2s |
Repeatability | Spectral Reflectance: standard deviation within 0.1 %400 ~ 700 nm : within 0.2% |
Colorimetric Value: Standard deviation within DeltaE*ab 0.04 ( Measurement conditions: white calibration plate measured 30 times at 5 seconds intervals after white calibration was performed.) | |
Inter Instrument Agreement | Within DeltaE*ab 0.2 (Average for 12 BCRA Series II color tiles) |
Display Screen | TFT 3.5inch, Capacitive Touch Screen |
Interface | USB/RS-232 |
Data Memory | 1000 Standards, 15000 Samples |
Standard Accessory | Power Adapter, Li-ion Battery, Operating Instruction, CD-ROM (containing management software), Data Line, White and Black Calibration Cavity, Protective Cover and Wrist Strap |
Spectro-Densitometers
3nh also offers a unique range of spectro-densitometers which are specifically used in industries such as printing, film processing, textile printing & dyeing, and plastic electronics. This is the reason they are sometimes referred to as pressroom densitometers. The 3nh spectro-densitometer models YD5050 and YD5010 measure and display the density of ink on a colour bar, based on which the operator can decide on adjusting the ink levels.
YD Spectrodensitometer Models:
- YD 5010
- YD 5050
Model | YD5010 |
Measurement Geometry | 45/0(45 ring-shaped illumination, 0 degree viewing angle); ISO 5-4,CIE No.15 |
Features | Common spectrophotometer densitometer, apply in ink printing, in Film Processing, Textile Printing and Dyeing, Plastic Electronics and Other Industries for Color Measurement and Quality Control;especially suitable for the measurement and quality control of optical density and dot enlargement in ink printing;able to customize single aperture Φ2mm,Φ4mm,Φ8mm. |
Light Source | Combined LED Light, UV Light |
Spectral separation device | Concave Grating |
Detector | 256 Image Element Double Array CMOS Image Sensor |
Wavelength Range | 400~700nm |
Wavelength Pitch | 10nm |
Half Bandwidth | 10nm |
Measurement Conditions | Compliance with ISO 13655 measurement conditions; |
Density Standards | ISO Status A, E, I, T |
Density index | Density value, density difference, dot area, dot enlargement, overprint, printing characteristics, printing contrast, tone error and gray level |
Measurement aperture | Customized one aperture:Φ2mm,Φ4mm,Φ8mm optional |
Color Spaces | CIE LAB,XYZ,Yxy,LCh |
Color Difference Formula | ΔE*ab,ΔE*94,ΔE*00 |
Other Colorimetric Index | / |
Observer Angle | 2°/10° |
Illuminants | A,C,D50,D55,D65,D75,F2,F7,F11,F12 |
Measurement Time | About 1.5s |
Repeatability | Density: Within 0.01 D |
Chromaticity value:within ΔE*ab 0.04 (When a white calibration plate is measured 30 times at 5 second intervals after white calibration) Except M3 | |
Inter-instrument Error | Within ΔE*ab 0.2 (Average for 12 BCRA Series II color tiles) Except M3 |
Measurement mode | Single Measurement, Average Measurement(2-99) |
Display | 3.5-inch TFT color LCD, Capacitive Touch Screen |
Data memory | 10000 pcs |
Standard Accessory | Power Adapter, USB Cable, Built-in li-ion battery, User Manual, software(download from the website),White and Black Calibration Board, Protective Cover,Polarization filter box,Locating Plate |
Model | YD5050 |
Measurement Geometry | 45/0(45 ring-shaped illumination, 0 degree viewing angle); ISO 5-4,CIE No.15 |
Features | high accuracy spectrophotometer densitometer, apply in ink printing, in Film Processing, Textile Printing and Dyeing, Plastic Electronics and Other Industries for Color Measurement and Quality Control;especially suitable for the measurement and quality control of optical density and dot enlargement in ink printing;able to customize single aperture Φ2mm,Φ4mm,Φ8mm. |
Light Source | Combined LED Light, UV Light |
Spectral separation device | Concave Grating |
Detector | 256 Image Element Double Array CMOS Image Sensor |
Wavelength Range | 400~700nm |
Wavelength Pitch | 10nm |
Half Bandwidth | 10nm |
Measurement Conditions | Compliance with ISO 13655 measurement conditions; M0 (CIE Light Soure A) M1 (CIE Light Soure D50) M2 (Excluding UV light source) M3 (M2+Polarized light filter) |
Density Standards | ISO Status A, E, I, T |
Density index | Density value, density difference, dot area, dot enlargement, overprint, printing characteristics, printing contrast, tone error and gray scale, density scanning |
Measurement aperture | Customized one aperture:Φ2mm,Φ4mm,Φ8mm optional |
Color Spaces | CIE LAB,XYZ,Yxy,LCh,CIE LUV,HunterLAB |
Color Difference Formula | ΔE*ab, ΔE*94, ΔE*00, ΔE*uv, ΔE*cmc(2:1), ΔE*cmc(1:1), ΔE(Hunter) |
Other Colorimetric Index | WI(ASTM E313,CIE/ISO,AATCC,Hunter), YI(ASTM D1925,ASTM 313), MI (Metamerism Index),Opacity, |
Observer Angle | 2°/10° |
Illuminants | A, C, D50, D55, D65, D75, F2(CWF), F7(DLP), F11(TL84), F12(TL83/U30), F1, F3, F4, F5, F6, F8, F9, F10(TPL5) |
Measurement Time | About 1.5s |
Repeatability | Density: Within 0.01 D |
Chromaticity value:within ΔE*ab 0.03 ( When a white calibration plate is measured 30 times at 5 second intervals after white calibration) Except M3 | |
Inter-instrument Error | Within ΔE*ab 0.18 (Average for 12 BCRA Series II color tiles) Except M3 |
Measurement mode | Single Measurement, Average Measurement(2-99) |
Display | 3.5-inch TFT color LCD, Capacitive Touch Screen |
Interface | USB, Bluetooth 4.0 |
Data memory | 20000 pcs |
Standard Accessory | Power Adapter, USB Cable, Built-in li-ion battery, User Manual, software(download from the website),White and Black Calibration Board, Protective Cover,Polarization filter box,Locating Plate |
Grating Spectrophotometers
3nh manufacture both bench-top and portable models of grating spectrophotometers. TS7600 and TS7700 are the portable models while the bench-top variants are YS6010 and YS6060.
The portable models are equipped with a silicon photodiode array sensor and an integrating sphere size of Φ40mm. Both the systems can measure various colour spaces such as CIE LAB, XYZ, Yxy, LCh, CIE LUV, and s-RGB. The TS770 has a UV light source in addition to the conventional combined full spectrum LED light source and can provide colour values in the popular HunterLab colour space. They are equipped with TFT colour touch screens for easy operation and navigation.
The bench top models are preferred for R&D applications in laboratory environments. The YS6010 and YS6060 are equipped with an integrating sphere size of Φ154mm and wavelength range of 360 – 780 nm. These systems are equipped with a high-quality 256 image element double array CMOS image sensor. The YS6010 and YS6060 colour spectrophotometers are equipped with built-in memories that can store up to 20,000 and 40,000 results each.
Grating Spectrophotometer Models:
- TS 6700
- TS 7700
- YS 6010
- YS 6060
Model | TS7600 |
Optical Geometry | Reflect: di:8°, de:8°(diffused illumination, 8-degree viewing angle); |
Characteristic | Customized one aperture, It is used for precise color measurement and quality control in plastic electronics, paint and ink, textile and garment printing and dyeing, printing, ceramics and other industries, and for fluorescent sample measurement. |
Integrating Sphere Size | Φ40mm |
Light Source | Combined full spectrum LED light source |
Spectrophotometric Mode | Flat Grating |
Sensor | Silicon photodiode array (double row 40 groups) |
Wavelength Range | 400~700nm |
Wavelength Interval | 10nm |
Semiband Width | 10nm |
Measured Reflectance Range | 0-200% |
Measuring Aperture | Customized one aperture: MAV:Φ8mm/Φ10mm;SAV:Φ4mm/Φ5mm |
Specular Component | SCI&SCE |
Color Space | CIE LAB,XYZ,Yxy,LCh,CIE LUV,s-RGB,βxy,Munsell(C/2) |
Color Difference Formula | ΔE*ab,ΔE*uv,ΔE*94,ΔE*cmc(2:1),ΔE*cmc(1:1),ΔE*00 |
Other Colorimetric Index | WI(ASTM E313,CIE/ISO,AATCC,Hunter), |
Observer Angle | 2°/10° |
Illuminant | D65,A,C,D50,F2(CWF),F7(DLF),F10(TPL5),F11(TL84),F12(TL83/U30) |
Displayed Data | Spectrogram/Values, Samples Chromaticity Values, Color Difference Values/Graph, PASS/FAIL Result, Color Offset |
Measuring Time | About 1.5s (Measure SCI & SCE about 3.2s) |
Repeatability | Spectral reflectance: MAV/SCI, Standard deviation within 0.1% (400 nm to 700 nm: within 0.2%) |
Inter-instrument Error | MAV/SCI, Within ΔE*ab 0.2 |
Measurement Mode | Single Measurement, Average Measurement(2-99times) |
Locating Method | Camera Locating,stabilizer cross position |
Displayed Data | 3.5-inch TFT color LCD, Capacitive Touch Screen |
Data Port | USB |
Data Storage | Standard 1000 Pcs, Sample 20000 Pcs |
Standard Accessory | Power Adapter, User Guide, PC Software(Download from office website), USB cable, White and Black Calibration Cavity, Protective Cover, Wrist strap, One aperture (8mm or 4mm) |
Model | TS7700 |
Optical Geometry | Reflect: di:8°, de:8°(diffused illumination, 8-degree viewing angle) |
SCI (specular component included)/SCE (specular component excluded) ; Include UV / excluded UV light source | |
Conforms to CIE No.15,GB/T 3978,GB 2893,GB/T 18833,ISO7724-1,ASTM E1164,DIN5033 Teil7 | |
Characteristic | double apertures for accurate color analysis and transmission in laboratory |
It is used for precise color measurement and quality control in plastic electronics, paint and ink, textile and garment printing and dyeing, printing, ceramics and other industries, and for fluorescent sample measurement. | |
Integrating Sphere Size | Φ40mm |
Light Source | Combined full spectrum LED light source, UV light source |
Spectrophotometric Mode | Flat Grating |
Sensor | Silicon photodiode array (double row 40 groups) |
Wavelength Range | 400~700nm |
Wavelength Interval | 10nm |
Semiband Width | 10nm |
Measured Reflectance Range | 0-200% |
Measuring Aperture | MAV:Φ8mm/Φ10mm;SAV:Φ4mm/Φ5mm |
Specular Component | SCI&SCE |
Color Space | CIE LAB,XYZ,Yxy,LCh,CIE LUV,s-RGB,HunterLab,βxy,DIN Lab99 Munsell(C/2) |
Color Difference Formula | ΔE*ab,ΔE*uv,ΔE*94,ΔE*cmc(2:1),ΔE*cmc(1:1),ΔE*00, DINΔE99,ΔE(Hunter) |
Other Colorimetric Index | WI(ASTM E313,CIE/ISO,AATCC,Hunter), |
YI(ASTM D1925,ASTM 313), | |
Metamerism Index MI, | |
Staining Fastness, Color Fastness, Color Strength, Opacity, | |
8° Glossiness,555 tone classification | |
Observer Angle | 2°/10° |
Illuminant | D65,A,C,D50,D55,D75,F1,F2(CWF),F3,F4,F5,F6,F7(DLF),F8,F9,F10(TPL5),F11(TL84),F12(TL83/U30) |
Displayed Data | Spectrogram/Values, Samples Chromaticity Values, Color Difference Values/Graph, PASS/FAIL Result, Color Offset |
Measuring Time | About 1.5s (Measure SCI & SCE about 3.2s) |
Repeatability | Spectral reflectance: MAV/SCI, Standard deviation within 0.08% (400 nm to 700 nm: within 0.18%) |
Chromaticity value: MAV/SCI, within ΔE*ab 0.02 ( When a white calibration plate is measured 30 times at 5 second intervals after white calibration) | |
Inter-instrument Error | MAV/SCI, Within ΔE*ab 0.15 |
Measurement Mode | Single Measurement, Average Measurement(2-99times) |
Locating Method | Camera Locating,stabilizer cross position |
Dimension | L*W*H=129X76X217mm |
Weight | Approx 600g |
Battery | 3.7V,5000mAh Li-ion battery, 6000 measurements within 8 hours |
Illuminant Life Span | 5 years, more than 3 million times measurements |
Displayed Data | 3.5-inch TFT color LCD, Capacitive Touch Screen |
Data Port | USB, Bluetooth 4.2 |
Data Storage | Standard 1000 Pcs, Sample 30000 Pcs |
Standard Accessory | Power Adapter, User Guide, PC Software(Download from office website), USB cable, White and Black Calibration Cavity, Protective Cover, Wrist strap, 8mm flat aperture, 8mm tip aperture, 4mm flat aperture, 4mm tip aperture |
Optional Accessory | Micro Printer, Powder Test Box |
Model | YS6010 Benchtop Spectrophotometer |
Optical Geometry | Reflect: di:8°, de:8°(diffused illumination, 8-degree viewing angle) ; |
Application | It is used for accurate analysis and transmission of laboratory color. Apply in paints, inks, textiles, garments, printing and dyeing, printing etc industries for color transfer and quality control. |
Integrating Sphere Size | Φ154mm |
Light Source | 360 nm to 780 nm, Combined LED Light, 400nm cut-off light source |
Spectrophotometric Mode | Concave Grating |
Sensor | 256 Image Element Double Array CMOS Image Sensor |
Wavelength Range | 360-780nm |
Wavelength Interval | 10nm |
Semiband Width | 10nm |
Measured Reflectance Range | 0-200% |
Measuring Aperture | Reflective: Φ30mm/Φ25.4mm, Φ10mm/Φ8mm, Φ6mm/Φ4mm; |
Specular Component | Reflectance: SCI&SCE / Transmittance: SCI&SCE |
Color Space | CIE LAB,XYZ,Yxy,LCh,CIE LUV,Musell,s-RGB,HunterLab,βxy,DIN Lab99 |
Color Difference Formula | ΔE * ab ,ΔE * uv ,ΔE * 94 ,ΔE * cmc(2:1) ,ΔE * cmc(1:1) ,ΔE * 00 , DINΔE 99 ,ΔE (Hunter), |
Other Colorimetric Index | WI (ASTM E313, CIE/ISO, AATCC, Hunter), |
Observer Angle | 2°/10° |
Illuminant | D65,A,C,D50,D55,D75,F1,F2,F3,F4,F5,F6,F7,F8,F9,F10,F11,F12,CWF,DLF,TL83,TL84,TPL5,U30 |
Displayed Data | Spectrogram/Values, Samples Chromaticity Values, Color Difference Values/Graph, PASS/FAIL Result, Color Offset |
Measuring Time | About 2.4s (Measure SCI & SCE about 5s) |
Repeatability | Spectral reflectance: Φ25.4mm/SCI, Standard deviation within 0.05% (400 nm to 700 nm: within 0.04%) |
Inter-instrument Error | Φ25.4mm/SCI, Within ΔE*ab 0.15 |
(Average for 12 BCRA Series II color tiles) | |
Illuminant Life Span | 5 years, more than 3 million times measurements |
Display | 7-inch TFT color LCD, Capacitive Touch Screen |
Data Port | USB & Print serial port |
Data Storage | Standard 2000 Pcs, Sample 20000 Pcs |
Standard Accessory | Power Adapter, User Guide, CD Disk(PC Software), USB cable, Standard Calibration Board, Black Calibration Cavity, Transmission black baffle, Sample holder, 25.4 caliber, 8 caliber, 4 caliber |
Optional Accessory | Micro-printer, Transmissive Test Component, Micro Aperture(4mm) transmission test clamp component, Instrument inversion components,culture d |
Model | YS6060 Benchtop Spectrophotometer |
Optical Geometry | Reflect: di:8°, de:8°(diffused illumination, 8-degree viewing angle) ; |
Application | It is used for accurate analysis and transmission of laboratory color. Apply in paints, inks, textiles, garments, printing and dyeing, printing etc industries for color transfer and quality control. |
Integrating Sphere Size | Φ154mm |
Light Source | 360 nm to 780 nm, Combined LED Light, 400nm cut-off light source,420nmCut-off light source |
Spectrophotometric Mode | Concave Grating |
Sensor | 256 Image Element Double Array CMOS Image Sensor |
Wavelength Range | 360-780nm |
Wavelength Interval | 10nm |
Semiband Width | 5nm |
Measured Reflectance Range | 0-200% |
Measuring Aperture | Reflective : Φ30mm/Φ25.4mm, Φ18mm/Φ15mm, Φ10mm/Φ8mm, Φ6mm/Φ4mm; |
Specular Component | Reflectance: SCI&SCE / Transmittance: SCI&SCE |
Color Space | CIE LAB,XYZ,Yxy,LCh,CIE LUV,Musell,s-RGB,HunterLab,βxy,DIN Lab99 |
Color Difference Formula | ΔE * ab ,ΔE * uv ,ΔE * 94 ,ΔE * cmc(2:1) ,ΔE * cmc(1:1) ,ΔE * 00 , DINΔE 99 ,ΔE (Hunter), |
Other Colorimetric Index | WI (ASTM E313, CIE/ISO, AATCC, Hunter), |
Observer Angle | 2°/10° |
Illuminant | D65,A,C,D50,D55,D75,F1,F2,F3,F4,F5,F6,F7,F8,F9,F10,F11,F12,CWF,DLF,TL83,TL84,TPL5,U30 |
Displayed Data | Spectrogram/Values, Samples Chromaticity Values, Color Difference Values/Graph, PASS/FAIL Result, Color Offset |
Measuring Time | About 2.4s (Measure SCI & SCE about 5s) |
Repeatability | Spectral reflectance: Φ25.4mm/SCI, Standard deviation within 0.04% (400 nm to 700 nm: within 0.04%) |
Inter-instrument Error | Φ25.4mm/SCI, Within ΔE*ab 0.12 |
| (Average for 12 BCRA Series II color tiles) |
Dimension | L*W*H=370x300x200mm |
Illuminant Life Span | 5 years, more than 3 million times measurements |
Display | 7-inch TFT color LCD, Capacitive Touch Screen |
Data Port | USB & Bluetooth & Print serial port |
Data Storage | Standard 5000 Pcs, Sample 40000 Pcs |
Standard Accessory | Power Adapter, User Guide, CD Disk(PC Software), USB cable, Standard Calibration Board, Black Calibration Cavity, Transmission black baffle, Sample holder, 25.4 caliber, 15 caliber, 8 caliber, 4 caliber,Transmissive Test Component |
Optional Accessory | Micro-printer, Micro Aperture(4mm) transmission test clamp component, Instrument inversion components,culture dish |
Additional Accessories To Colour Spectrophotometers
Powder Test Box
For efficient measurement of the colour of powders, pellets, granules, and products of their like, the powder test box is a vital accessory. The powder test box should be filled up to 1/3rds of its capacity and attached to the spectrophotometer to measure colour values of the sample.
Universal Test Component
The universal test component is an accessory spectrophotometers which is used for assessing the colour of liquids, powders, and pastes.
3nh Colour Spectrophotometer Applications
- Plastics
- Paints & inks
- Printing
- Cosmetics
- Textile
- Leather
- Paper
- Food
3nh Colour Spectrophotometer Price